{"id":2602,"date":"2020-06-29T13:30:05","date_gmt":"2020-06-29T13:30:05","guid":{"rendered":"http:\/\/ninzio.com\/octavian\/?p=2602"},"modified":"2021-07-08T13:36:12","modified_gmt":"2021-07-08T13:36:12","slug":"off-grid-battery-options","status":"publish","type":"post","link":"https:\/\/prismadzen.com\/index.php\/2020\/06\/29\/off-grid-battery-options\/","title":{"rendered":"Off-Grid Battery Options"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<h2 class=\"deeper-text align-left \" style=\"font-size:26px;font-weight:900;line-height:40px;\" ><span>Lead-Acid<\/span>\n<\/h2><\/p>\n<p><span style=\"font-weight: 400;\">Until recently, traditional<\/span><span style=\"font-weight: 400;\"> lead-acid deep cycle<\/span><span style=\"font-weight: 400;\"> battery systems were the most common and reliable option for off-grid systems. Lead-acid batteries are a proven technology and can last up to 15 or more years if they are not held at elevated temperatures (above 40 degC), and are not regularly discharged too low. Lead-acid batteries require precise battery charging following a specific charge cycle plus temperature sensors to adjust voltage settings. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Most well known <\/span><span style=\"font-weight: 400;\">off-grid inverter\/chargers<\/span><span style=\"font-weight: 400;\"> offer programmable charge voltage settings along with sensors to precisely charge under all conditions. Lead-acid deep cycle batteries are still widely used and offer several advantages over lithium.<\/span><\/p>\n<blockquote><p><span style=\"font-weight: 400;\">Lead-acid deep cycle battery options &#8211; 2V, 6V or 12V options and various types &#8211; Gel, AGM, Flooded<\/span><\/p><\/blockquote>\n<p><span style=\"font-weight: 400;\">One of the most significant\u00a0<\/span><b>benefits\u00a0<\/b><span style=\"font-weight: 400;\">of lead-acid batteries is unlike modern lithium batteries; the battery will not shut-down at a low voltage or low state of charge (SOC). This is important, especially in emergencies or when a backup generator fails. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Lead-acid batteries can be discharged down to 0% state of charge if needed for backup, but it is not recommended as it can severely reduce the life of the battery.<\/span><\/p>\n<p>[\/vc_column_text]<div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":60,\"mobile\":60,\"smobile\":60}'><\/div><div class=\"deeper-content-box clearfix ctb-712185828\" style=\"\" data-config='{\"padding\":\"0\",\"mobiPadding\":\"0\",\"margin\":\"0\",\"mobiMargin\":\"0\",\"round\":\"10px\",\"borderStyleHover\":\"solid\"}'>\r\n\t\t\t\t\t<div class=\"inner \" style=\"overflow:hidden;\">\r\n\t\t\t\t\t\t\n\t\t\t<div class=\"deeper-carousel-box  column-1 column2-1 column3-1 column4-1 gap-0\" data-config='{\"cellAlign\":\"left\",\"autoPlay\":3000,\"fullAside\":false,\"wrapAround\":false,\"groupCells\":false}'>\n\t\t\t\t[vc_single_image image=&#8221;3127&#8243; img_size=&#8221;full&#8221;][vc_single_image image=&#8221;3126&#8243; img_size=&#8221;full&#8221;][vc_single_image image=&#8221;3127&#8243; img_size=&#8221;full&#8221;]\t\t\t<\/div><!-- \/.deeper-carousel-box -->\n\n\t\t\t\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\r\n\t\t\t\t<\/div><div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":60,\"mobile\":60,\"smobile\":60}'><\/div>\n<p>[vc_column_text] <span style=\"font-weight: 400;\">In certain applications high performance <\/span><b>lead-acid batteries<\/b><span style=\"font-weight: 400;\"> are still an excellent choice for off-grid systems. Lead-acid is a well proven and reliable technology which is compatible with virtually all off-grid inverters and solar charge controllers. Lead-acid battery banks can also be more reliable in some situations as the battery will not automatically shut down in extreme temperatures or when low state of charge is reached. In addition, they can be easily recycled using existing infrastructure. [\/vc_column_text]<\/span><\/p>\n<p><h2 class=\"deeper-text align-left \" style=\"font-size:26px;font-weight:900;line-height:40px;\" ><span>Advantages<\/span>\n<\/h2><div class=\"deeper-text align-left \" style=\"\" ><ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Compatibility with most inverters.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Proven and trusted technology.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Safe, very low risk (sealed Gel\/AGM).<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Battery will not cut out at low\u00a0 voltage**<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Long life (if not over discharged)\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Easily recycled.<\/span><\/li>\n<\/ul>\n<\/div>\n<p><h2 class=\"deeper-text align-left \" style=\"font-size:26px;font-weight:900;line-height:40px;\" ><span>Disadvantages<\/span>\n<\/h2><div class=\"deeper-text align-left \" style=\"\" ><ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Lower efficiency &#8211; around 80%<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Low energy density &#8211; Very heavy<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Usable capacity limited &#8211; Max 40% DoD on regular basis<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Not modular &#8211; Fixed size once installed<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cannot sustain partial state of charge for long periods<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High temperatures can drastically reduce battery life<\/span><\/li>\n<\/ul>\n<blockquote><span>\n<span style=\"font-weight: 400;\">** Cutout voltage &amp; SOC based on inverter settings and rate of discharge<\/span>\n<\/span><\/blockquote>\n<\/div>\n<p><h2 class=\"deeper-text align-left \" style=\"font-size:26px;font-weight:900;line-height:40px;\" ><span>Lithium-Ion<\/span>\n<\/h2>[vc_column_text]<\/p>\n<p><span style=\"font-weight: 400;\">More recently <\/span><b>lithium-ion battery<\/b><span style=\"font-weight: 400;\"> systems have become extremely popular due to the high efficiency (92% to 98%), compact size, lightweight and scalability. In contrast, lead-acid battery banks have a fixed size or capacity whereas lithium systems do not suffer this limitation. This flexible sizing allows for additional capacity to be added at a later stage, which is a real bonus for both installers and customers alike.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Lithium batteries have a much higher energy density compared to lead-acid and are therefore lighter and more compact. A huge advantage of lithium is the ability to sustain a low state of charge (partial state of charge) for a prolonged amount of time without any negative effects such as sulfation which is a common problem with lead-acid batteries. Also, extremely high charge rates can be achieved using lithium with charging times up to 70% faster than lead-acid.<\/span><\/p>\n<p>[\/vc_column_text]<\/p>\n<div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":60,\"mobile\":60,\"smobile\":60}'><\/div><div class=\"deeper-content-box clearfix ctb-174225042\" style=\"\" data-config='{\"padding\":\"0\",\"mobiPadding\":\"0\",\"margin\":\"0\",\"mobiMargin\":\"0\",\"round\":\"10px\",\"borderStyleHover\":\"solid\"}'>\r\n\t\t\t\t\t<div class=\"inner \" style=\"overflow:hidden;\">\r\n\t\t\t\t\t\t\n\t\t\t<div class=\"deeper-carousel-box  column-1 column2-1 column3-1 column4-1 gap-0\" data-config='{\"cellAlign\":\"left\",\"autoPlay\":3000,\"fullAside\":false,\"wrapAround\":false,\"groupCells\":false}'>\n\t\t\t\t[vc_single_image image=&#8221;3139&#8243; img_size=&#8221;full&#8221;][vc_single_image image=&#8221;3138&#8243; img_size=&#8221;full&#8221;][vc_single_image image=&#8221;3139&#8243; img_size=&#8221;full&#8221;]\t\t\t<\/div><!-- \/.deeper-carousel-box -->\n\n\t\t\t\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\r\n\t\t\t\t<\/div><div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":60,\"mobile\":60,\"smobile\":60}'><\/div>\n<p><h2 class=\"deeper-text align-left \" style=\"font-size:26px;font-weight:900;line-height:40px;\" ><span>Advantages<\/span>\n<\/h2><div class=\"deeper-text align-left \" style=\"\" ><ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Very high efficiency &#8211; Approx 97%<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Very high energy density &#8211; Compact and Lightweight<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High charge and discharge rates allowed<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">No degradation issues with partial state of charge<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Modular and scalable systems (upgradable)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Safe and low risk (if charged correctly)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Most lithium batteries come with above 5 years warranty<\/span><\/li>\n<\/ul>\n<\/div>\n<p><h2 class=\"deeper-text align-left \" style=\"font-size:26px;font-weight:900;line-height:40px;\" ><span>Disadvantages<\/span>\n<\/h2><div class=\"deeper-text align-left \" style=\"\" ><ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Can shutdown at high temperatures (45+ degC)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Can shutdown at low temperatures (below 5 degC)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Can \u2018trip off\u2019 under continuous high surge loads.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">More difficult to recycle at end of life.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">May not function without a compatible inverter.<\/span><\/li>\n<\/ul>\n<\/div>\n<div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":60,\"mobile\":60,\"smobile\":60}'><\/div><h2 class=\"deeper-text align-left \" style=\"font-size:26px;font-weight:900;line-height:40px;\" ><span>The Heart Of An Off-Grid System &#8211; The Battery Inverter\/Charger<\/span>\n<\/h2><\/p>\n<p>[vc_column_text]<\/p>\n<p><span style=\"font-weight: 400;\">Modern off-grid solar systems use multi-mode inverters\/chargers to manage batteries, solar, and back-up power sources such as a generator. The inverter\/charger is the central energy management unit and can be either AC coupled with solar inverter\/s, or DC coupled with solar charge controller\/s, or both. Read more about <\/span><span style=\"font-weight: 400;\">AC and DC coupled systems<\/span><span style=\"font-weight: 400;\"> here.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Early off-grid systems used basic battery inverters and were very simple in comparison as the battery charger was a separate unit. These simple inverters generally had low power rating below 2kW and thus were only capable of powering low energy appliances like lights, fans and small pumps.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">little more a is well worth it for the power and features needed for a reliable off-grid system. The impressive features and high performance<\/span><\/p>\n<p>[\/vc_column_text]<\/p>\n<div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":60,\"mobile\":60,\"smobile\":60}'><\/div><h2 class=\"deeper-text align-left \" style=\"font-size:26px;font-weight:900;line-height:40px;\" ><span>DSP SOLAR SINE basic specifications<\/span>\n<\/h2><\/p>\n<p>[vc_column_text]<\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Type: <\/b><span style=\"font-weight: 400;\">Multi-mode Inverter\/charger (AC or DC coupled)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Use:<\/b><span style=\"font-weight: 400;\"> Solar storage, back-up (UPS), off-grid<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Sizes available (power output):<\/b><span style=\"font-weight: 400;\"> 1.0kW, 2kW, 3.0kW, 5kW,7.5kW<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Battery System Voltages:12V,<\/b><span style=\"font-weight: 400;\">24V, 48V, 72V,96V&amp;120V<\/span><\/li>\n<\/ul>\n<p>[\/vc_column_text]<\/p>\n<div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":60,\"mobile\":60,\"smobile\":60}'><\/div><h2 class=\"deeper-text align-left \" style=\"font-size:26px;font-weight:900;line-height:40px;\" ><span>Highlight<\/span>\n<\/h2><\/p>\n<p>[vc_column_text]<\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Very high surge power output (3 x rated cont. power)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Battery sense monitoring and mid string sensor for precise battery charging (lead-acid Gel and AGM)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Managed AC coupling\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Very powerful software package\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Unique pre-charge feature for safer start-up<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">AC \/ DC coupling capability<\/span><\/li>\n<\/ul>\n<p>[\/vc_column_text]<\/p>\n<p>[\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] Until recently, traditional lead-acid deep cycle battery systems were the most common and reliable option for off-grid systems. Lead-acid batteries are a proven technology and can last up to 15 or more years if they are not held at elevated temperatures (above 40 degC), and are not regularly discharged<\/p>\n","protected":false},"author":1,"featured_media":3137,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2602","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-prismads"],"_links":{"self":[{"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/posts\/2602","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/comments?post=2602"}],"version-history":[{"count":13,"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/posts\/2602\/revisions"}],"predecessor-version":[{"id":3146,"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/posts\/2602\/revisions\/3146"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/media\/3137"}],"wp:attachment":[{"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/media?parent=2602"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/categories?post=2602"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prismadzen.com\/index.php\/wp-json\/wp\/v2\/tags?post=2602"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}